Chauvin Arnoux PEL 104 Power Energy Logger

£1,739.00 Ex VAT

Chauvin Arnoux PEL104 Power Energy Logger

The Chauvin Arnoux PEL104 Power Energy Logger is an exceptionally well-built piece of kit designed to be suitable for all types of electrical networks. Automatically recognising the sensors connected, the PEL 104 includes 4 voltage inputs alongside 3 current inputs and crucially, can be operated without having to cut off the mains power supply. This power logger measures and records all the relevant data for energy consumption diagnostics, recording continuously with only a brief interval of 200ms between each measurement. Capable of 5 readings per second and recorded simultaneously on each phase, all data is captured as per the IEEE 1459 standard. Thanks to vast measurement ranges, voltage up 1,000 VAC/VDC and current up to 10 kVAC / 5 kVDC, the PEL 104 can log power values up to 10 GW/GVar/GVA, and energy up to 4 EWh/EVAh/EVarh. This makes the 104 ideal for energy usage analyses, load studies, energy surveys and complying with the energy audit requirements of ISO 50001 and EN 16247-3.

The PEL104 Power Energy Logger performs the following measurements:

  • RMS and DC measurements with 128 samples/cycle – simultaneously on each phase
  • AC and/or DC voltages up to 1000 V
  • Current up to 10 kA AC or 5 kA DC (depending on the current sensor)
  • Energy values up to 4 EWh / 4 EVAh / 4 EVarh & total energy (4 quadrants)
  • Phase data: cos φ, tan Φ, power factor (PF)
  • Crest factor
  • Harmonics up to the 50th order for currents and voltages
  • DC, 50 Hz, 60 Hz and 400 Hz measurements

Key Features

  • Suitable for all types of electrical networks
  • Provides real-time oversight
  • Automatically recognises connected sensors
  • 4 voltage inputs and 3 current inputs
  • Operates without having to cut off mains power supply
  • Measures/records all energy consumption diagnostics data
  • Interval of 200ms between each measurement
  • 5 readings per second recorded simultaneously on each phase
  • Voltage range up 1,000 VAC/VDC
  • Current range up to 10 kVAC / 5 kVDC
  • Log power values up to 10 GW/GVar/GVA
  • Log energy up to 4 EWh/EVAh/EVarh
  • RMS and DC measurements with 128 samples/cycle – simultaneously on each phase
  • AC and/or DC voltages up to 1000 V
  • Phase data functions: cos φ, tan Φ, power factor (PF)
  • THD calculation for currents and voltages
  • Harmonics up to the 50th order for currents and voltages
  • DC, 50 Hz, 60 Hz and 400 Hz measurements
  • Suitable for workshop, factory, agency or building environments
  • Recordings are all time & date stamped
  • Built-in customisable Alarm mode
  • Large SD card ideal for lengthy measurement campaigns.
  • Communication modes; WiFi, 3G-UMTS/GPRS, LAN (Ethernet), Bluetooth, USB ports
  • Monitor measurements & recover data from anywhere in the world
  • Insert a SIM card for remote connection via a GSM 3G link
  • IRD server emails user should an alarm be triggered
  • Use the IRD server to view measurements remotely via the internet
  • Compatible with FREE multilingual Android App
  • Communicate via Bluetooth with the device through smart device
  • Built-in software sensor enables measurements for applications on motors
  • Motor measurements; rotation speed, torque & engine efficiency
  • Wi-Fi interface for PC access
  • PEL Transfer software analyses data and calculates cost of power consumed Software results displayed in selected currency
  • DataView processing software creates certified or customised reports
  • Self-powered via its voltage inputs up to 600 V
  • Backlit LCD screen with triple digital display
  • Compact magnetised casing, extremely portable
  • No impact on electrical cabinets
  • Data recorded as per the IEEE 1459 standard
  • Rated IP54, 1000V CAT III and 600V CAT IV
What’s In The Box?
  • Chauvin Arnoux PEL104 Power Energy Logger
  • Self powering adaptor (P01102134)
  • 4 x voltage cables
  • 4 x crocodile clips
  • Set of rings/inserts
  • 600 V mains adapter
  • SD card
  • SD – USB adapter
  • USB cable
  • PC PEL TRANSFER software & user’s manual to download from the website
  • Quick start guide
  • Carrying bag

Comparison Chart

Chauvin Arnoux PEL Series Comparison Table

PEL 102 PEL 103 PEL 104 PEL 106
Installation Type Single-phase, split-phase, three-phase (with or without neutral)
Number of Channels 4V & 3A with calculated nutral current 5V & 4A
Acquistion Speed 1s 1s 200ms 200ms
Calculated Powers P, Q & S P, Q & S P, N, S, Q1 & D P, N, S, Q1 & D
Total or Partial Energy
Display by Quadrants
Energy Cost Calculation
Energy Lost Calculation
Motor Rotation Speed
Motor Torque
Motor Efficiency
Bluetooth, Ethernet & USB
4-Line Backlit LCD Screen
Wi-Fi
3G & GPRS
Alarms/Reports by Email
Max. SD Card Memory 32Gb 32Gb 32Gb 32Gb
Self Powering Adaptor Optional Optional Included Built-In
External Analogue Inputs 8 using L452 8 using L452
Ingress Protection IP54 IP54 IP54 IP67

Reviews

There are no reviews yet.

Be the first to review “Chauvin Arnoux PEL 104 Power Energy Logger”

Your email address will not be published. Required fields are marked *