DiLog DL9204 Digital Multimeter

£49.00 Ex VAT

Description

The DiLog DL9204 is a perfect digital multimeter for anyone from professional electricians to electrical hobbyists. Manual ranging, easy to use with a large rotary dial and clear 2000 count LCD display, the DL9204 is an ideal method of carrying out testing of electrical parameters with ease.

This multimeter is capable of carrying out measurements of AC voltage from 100mV to 600V, DC voltage from 0.1mV up to 600V, DC current from 1μA up to 10A, resistance from 0.1Ω to 2000KΩ and also carries out battery testing (on both 1.5V and 9V batteries). A diode testing function is also included.

Although it doesn’t have memory storage, the DL9204 does come with a data hold function, allowing a value shown on the screen to be temporarily frozen while you jot it down or use it as a comparison against other values. The meter will also automatically shut itself down when left idle in order to conserve the battery life.

DiLog DL9204 Digital Multimeter Key Features

  • Manual ranging DMM
  • 2000 count LCD display
  • Rotary dial switch for changing between procedures
  • Data hold function
  • Auto power off function
  • 1.5V and 9V battery testing
  • CAT III 600V safety rating
  • Full range protection
  • AC voltage measurements from 100mV up to 600V
  • DC voltage from 0.1mV up to 600V
  • DC current from 1μA up to 10A
  • Resistance from 0.1Ω to 2000KΩ
  • Diode testing

What’s Included?

  • DiLog DL9204 Digital Multimeter
  • Soft Black Carry Case
  • Test Lead
  • 9V Battery

Tech Specs

Dilog DL9204 Technical Specifications

DC Voltage
Range Resolution Accuracy
200mV 0.1mV ±0.5 % of rdg ± 2 dgts
2000mV 1mV ±0.5 % of rdg ± 2 dgts
20V 0.01V ±0.5 % of rdg ± 2 dgts
200V 0.1V ±0.5 % of rdg ± 2 dgts
600V 1V ±0.5 % of rdg ± 2 dgts
Input Impedance 1MΩ
200mV Range Maximum Input 200V rms
Maximum Input 600V DC/AC
AC Voltage
Range Resolution Accuracy
200V 0.1V ±1.2 % of rdg ± 10 dgts
600V 1V ±1.2 % of rdg ± 10 dgts
Input Impedance 1MΩ
Frequency range 50 to 400Hz
Maximum Input 600V DC/AC
DC Current
Range Resolution Accuracy
2000μA 1μA ±1.0 % of rdg ± 2 dgts
20mA 10μA ±1.0 % of rdg ± 2 dgts
200mA 100μA ±1.2 % of rdg ± 2 dgts
10A 10mA ±2.0 % of rdg ± 2 dgts
Overload Protection mA uA range – 0.2A / 250V
fast blow Fuse; A range 10A / 250V fast Blow
Maximum Input  200mA 250V fast acting fuse
(30 seconds max every 15 minutes)
Resistance
Range Resolution Accuracy
200Ω 0.1Ω ±0.8% of rdg ± 2 dgts
2000Ω ±0.8% of rdg ± 2 dgts
20kΩ 0.01kΩ ±0.8% of rdg ± 2 dgts
200kΩ 0.1kΩ ±0.8% of rdg ± 2 dgts
2000kΩ 1kΩ ±1% of rdg ± 2 dgts
Input Protection 250V AC rms for 15 seconds max
Battery Test
Range Resolution Accuracy
9V 10mV ±1.0% of rdg ± 2 dgts
1.5V 10mV ±1.0% of rdg ± 2 dgts
Test Current 9V (6mA); 1.5V (100mA)
Input Protection 250V DC or 250V AC RMS
Diode Test
Test Current 1mA maximum
Open Circuit Voltage 2.8V dc typical
Overload Protection 250V dc or ac rms
Audible Continuity
Test Curent <0.3mA
Audible threshold Less than 30Ω
Overload Protection 250V DC or AC RMS
MISC
Dimensions/Weight 150 (H) x 70 (W) x 48 (D)/ 255g

Reviews

There are no reviews yet.

Be the first to review “DiLog DL9204 Digital Multimeter”

Your email address will not be published. Required fields are marked *