Tech Specs
Dilog DL9204 Technical Specifications
DC Voltage | ||
Range | Resolution | Accuracy |
200mV | 0.1mV | ±0.5 % of rdg ± 2 dgts |
2000mV | 1mV | ±0.5 % of rdg ± 2 dgts |
20V | 0.01V | ±0.5 % of rdg ± 2 dgts |
200V | 0.1V | ±0.5 % of rdg ± 2 dgts |
600V | 1V | ±0.5 % of rdg ± 2 dgts |
Input Impedance | 1MΩ | |
200mV Range Maximum Input | 200V rms | |
Maximum Input | 600V DC/AC | |
AC Voltage | ||
Range | Resolution | Accuracy |
200V | 0.1V | ±1.2 % of rdg ± 10 dgts |
600V | 1V | ±1.2 % of rdg ± 10 dgts |
Input Impedance | 1MΩ | |
Frequency range | 50 to 400Hz | |
Maximum Input | 600V DC/AC | |
DC Current | ||
Range | Resolution | Accuracy |
2000μA | 1μA | ±1.0 % of rdg ± 2 dgts |
20mA | 10μA | ±1.0 % of rdg ± 2 dgts |
200mA | 100μA | ±1.2 % of rdg ± 2 dgts |
10A | 10mA | ±2.0 % of rdg ± 2 dgts |
Overload Protection | mA uA range – 0.2A / 250V fast blow Fuse; A range 10A / 250V fast Blow |
|
Maximum Input | 200mA 250V fast acting fuse (30 seconds max every 15 minutes) |
|
Resistance | ||
Range | Resolution | Accuracy |
200Ω | 0.1Ω | ±0.8% of rdg ± 2 dgts |
2000Ω | 1Ω | ±0.8% of rdg ± 2 dgts |
20kΩ | 0.01kΩ | ±0.8% of rdg ± 2 dgts |
200kΩ | 0.1kΩ | ±0.8% of rdg ± 2 dgts |
2000kΩ | 1kΩ | ±1% of rdg ± 2 dgts |
Input Protection | 250V AC rms for 15 seconds max | |
Battery Test | ||
Range | Resolution | Accuracy |
9V | 10mV | ±1.0% of rdg ± 2 dgts |
1.5V | 10mV | ±1.0% of rdg ± 2 dgts |
Test Current | 9V (6mA); 1.5V (100mA) | |
Input Protection | 250V DC or 250V AC RMS | |
Diode Test | ||
Test Current | 1mA maximum | |
Open Circuit Voltage | 2.8V dc typical | |
Overload Protection | 250V dc or ac rms | |
Audible Continuity | ||
Test Curent | <0.3mA | |
Audible threshold | Less than 30Ω | |
Overload Protection | 250V DC or AC RMS | |
MISC | ||
Dimensions/Weight | 150 (H) x 70 (W) x 48 (D)/ 255g |