Tech Specs
Megger AVO410 Technical Specifications
Note: accuracy is ± (% of reading + number of digits) at 23°C ± 5°C, less than 80% RH
AC/DC Voltage | ||
---|---|---|
Range | DC Accuracy | AC Accuracy |
600.0mV | ±0.5% + 2 digits | 50Hz/60Hz sine wave for 600.0mV range, ± (0.9% + 5 digits) 50 to 500Hz *1 |
6.000V | ||
60.00V | ||
600V | ||
DC 1000V / AC 750V | ||
Overvoltage Protection | DC 1000V or AC | |
Input Impedance | 10MΩ // less than 100pF | |
CMRR (Common Mode Rejection Ratio/Normal Mode Rejection Ratio) |
VAC: CMRR>60dB at DC, 50Hz/60Hz | |
VDC: CMRR > 10dB at DC, 50/60Hz | ||
NMRR: >50dB at DC, 50/60Hz | ||
AC Conversion Type | AC conversions are AC courple True RMS responding, calibrated to the sine wave input | |
Note | *1 ) The basic accuracy is specified for a sine wave below 4000 counts. Over 4000 counts, add 0.6% to the accuracy. For non-sine waves below 2000 counts, refer to the following for accuracy:
±1.5% addition error for C.F from 1.4 to 3 |
|
Crest Factor | C.F = peak/rms | |
AC/DC Current | ||
Range | DC Accuracy | AC Accuracy |
600.0μA | ±(1.0% + 2 digits) | N/A |
6000μA | ||
6.000A | ±(1.5% + 6 dgt) 50Hz – 500Hz *1 | |
10.00A | ||
Overload Protection | A Input: 10A (500V) fast blow fuse | |
μA Input: 600V rms | ||
*1) AC Conversion Type | Conversion type and additional specification are the same AC/DC voltage | |
Resistance | ||
Range | Accuracy | Overload Protection |
600.0Ω * 2 | ±(0.7% + 2 digits) | 600V rms |
6.000kΩ | ||
60.00kΩ | ||
600.0kΩ | ||
6.000MΩ | ±(1.0% + 2 digits) | |
60.00MΩ * 1 | ±(1.5% + 2 digits) | |
*1) | Less than 20Hz, the sensitivity is 1.5V rms | |
*2) | Max sensitivity <5V AC rms | |
Capacitance | ||
Range | Accuracy | |
6.000nF | ±(1.9%) + 8 digits | |
60.00nF | ||
600.0nF | ||
6.000μF | ||
60.00μF | ||
600.0μF | ||
6.00mF* | ||
Overload Protection | 600V rms | |
* | <100 digit of reading rolling | |
General Specifications | ||
Display | 6000 counts, updates 1.5/sec | |
Polarity Indication | Automatic, positive implied, negative indicated | |
Overrange Indication | “OL” or “-OL” | |
Low Battery Indication | Displayed when the battery voltage drops below operating voltage | |
Auto Power Off | Approx 10 minutes | |
Operating Conditions | Non-condensing ≤10 °C, 11 °C ~ 30 °C (≤80% R.H) 31 °C ~ 40 °C (≤75% R.H), 41 °C ~ 50 °C (≤45% R.H) |
|
Storage Temperature | -20 to 60°C, 0 to 80% RH when battery removed from meter | |
Temperature Coefficient | 0.15 x (Spec.Acc’y) / °C, <18°C or >28°C | |
Safety | IEC 61010 CAT IV 600V | |
Power Requirements | Standard 9V battery: PP3, NEDA 1604, IEC6422 or JIS006P | |
Battery Life | Alkaline: 300 hours | |
Dimensions (W x H x D) | 76 x 158 x 38mm without holster | |
82 x 164 x 44mm with holster | ||
Weight | 522g |