Fluke 1664 FC Multifunction Tester Key Features

  • NEW – AutoTest mode – automatically performs 8 testing procedures, saving you time and effort!
  • NEW – Insulation PreTest safety function automatically checks to see if appliances are connected to the installation and will limit testing if there are
  • NEW – Insulation testing at L-N and N-PE inputs
  • Loop and line resistance measurements with mΩ resolution
  • NEW – Continuity testing at L-N and N-PE inputs
  • Test smooth, DC-sensitive RCDs
  • Earth resistance measurements
  • Voltage and frequency measurements
  • Wiring polarity checker
  • Insulation resistance measurements
  • Measure motor windings using the continuity test function
  • Loop and line resistance measurements
  • Prospective earth fault current (PEFC/IK) measurements
  • Prospective short circuit current measurements (PSC/IK)
  • RCD switching time function
  • RCD tripping level (ramp test)
  • RCD variable current
  • Automatic RCD test sequences
  • Phase sequence indicator
  • NEW – Fluke Connect enabled – wirelessly interface with your smartphone, tablet or other Fluke Connect testing tools to share data using the Fluke Cloud, make video calls and much more
  • NEW – On/off switchable auto starts for RCD and loop testing
  • Self-testing function
  • NEW – Z max memory
  • Built-in memory storage with USB download (requires optional Fluke software)
  • NEW – heavy duty, single input line cord

What’s Included?

  • Fluke 1664 FC Multifunction Tester
  • 6 x AA Cell Batteries
  • Hard Carrying Case
  • Zero Adapter
  • Mains Test Cord
  • Standard Test Lead Set
  • Padded Carrying Strap
  • Quick Reference Guide
  • Remote Test Probe

Include Calibration Certificate (+£0.00)

Tech Specs

Fluke 1600 Series Technical Specifications

AC/DC Voltage (TRMS)
Range Resolution Input Impedance Overload Protection
500V 0.1V 3.3MΩ 660V rms
Continuity Testing (Rlo)
Range (Autoranging) Resolution Open Circuit Voltage
20Ω 0.01Ω >4V
200Ω 0.1Ω
2000Ω
Insulation Resistance Measurement (Riso)
Model Number Test Voltages
1662 100, 250, 500 and 1000V
1663/1664 FC 50, 100, 250, 500 and 1000V
Test Voltage Insulation Resistance Range Resolution Test Current
50V 20MΩ/50MΩ 0.01MΩ/0.1MΩ 1mA @ 50kΩ
100V 20MΩ/100MΩ 0.01MΩ/0.1MΩ 1mA @ 100kΩ
250V 20MΩ/200MΩ 0.01MΩ/0.1MΩ 1mA @ 250kΩ
500V 20MΩ/200MΩ/500MΩ 0.01MΩ/0.1MΩ/1MΩ 1mA @ 500kΩ
1000V 20MΩ/200MΩ/1000MΩ 0.01MΩ/0.1MΩ/1MΩ 1mA @ 1MΩ
Insulation Pretest
Insulation Safety Pretest Requires the unit to be connected to L, N and PE
Loop and Line Impedance (Zi)
Range Resolution
10Ω (Hi current mΩ mode) 20Ω/200Ω/2000Ω 1mΩ / 0.01Ω / 0.1Ω / 1Ω
RCD Testing
Model Number Types Tested
1662 AC, G, S, A/F
1663/1664 FC A/F, AC, B/B+, G and S
RCD Trip Time Test (ΔT)
Current Range Step Size Dwell Time Measurement Accuracy
Type G Type S
30 to 110% of RCD Rated Current 10% of index IΔN 300ms/step 500ms/step ±5%
Notes
30 % to 210 % for Type A IΔN = 10mA
20 % to 210 % for Type B
Specified trip current ranges (EN 61008-1):
50 % to 100 % for Type AC
35 % to 140 % for Type A (>10 mA)
35 % to 200 % for Type A (≤10 mA)
50 % to 200 % for Type B
Earth Resistance Test (RE) – Only Available On 1664 FC and 1663
Range Resolution Frequency Output Voltage
200Ω 0.1Ω 128Hz 25V
2000Ω 128Hz 25V
Phase Sequence Indication
Icon Range Display
Shows icon when active 100 to 500V 1-2-3 or 3-2-1
General Specifications
Dimensions 10cm (L) x 25cm (W) x 12.5cm (H)
Weight (Including Batteries) Approx 1.3kg
Battery Size 1.5V type AA (IEC LR6) x 6
Sealing IP40
Safety Complies with IEC/EN61010-1, UL61010, ANSI/ISA – s82.02.01 and CAN/CSA c22.2 No. 1010
Overvoltage CAT III 500V, CAT IV 300V
Performance EC/EN61557-1 to IEC/EN61557-7 and IEC/EN61557-10

Comparison Chart

Fluke 1660 Series Differences

There are three models in the 1600 series – the 1662, the 1663 and the 1664 FC.

This table outlines the difference between the three units.

Measurement Function 1662 1663 1664 FC
Insulation-PreTest Safety Function NEW
Insulation at L-N, L-PE and N-PE inputs NEW
Auto Test Sequence NEW
Loop and Line Resistance with mΩ Resolution
Continuity at L-N, P-PE and N-PE Inputs NEW
Test Smooth, DC-Sensitive RCDs (Type B/B+)
Earth Resistance
Voltage TRMS (AC/DC) and Frequency
Wiring Polarity Checker (Detects Broken PE and N Wires)
Insulation Resistance
Continuity and Resistance
Measure Motor Windings with Continuity Test (@10mA)
Loop/Line Resistance
Prospective Earth Fault Current (PEFC/IK)
Prospective Short-Circuit Current (PSC/IK)
RCD Trip Time
RCD Trip Current (Ramp Test)
Measure Trip Time/Current for RCD type A/AC in One Test
RCD Variable Test Current
Automatic RCD Test Sequence
Phase Sequence Test
Other Features
Fluke Connect Compatibility NEW
ShareLive Calling NEW
Fluke Cloud Stroage NEW
On/Off Switchable Auto Start for RCD and Loop Tests
Self Test
Illuminated Display
Memory/Interface
Z Max Memory NEW
Memory
IR-USB and BLE Interface (use with optional Fluke DMS software and FVF) IR-USB IR-USB/BLE

Reviews